Ex Control Stations for Individual Configuration
Moulded-plastic version for Zone 1. 21 2 and 21
CEAG control stations can be combined according to customers‘ specifications. Quick fixing allows up to three CEAG built-in components, such as signal lamps, pushbuttons and switches, to be snapped on a rail in the enclosure. The enclosures consist of low-temperature impact-resistant thermoplastic which fulfils the requirements of EN 60079 and provides a high resistance to chemicals. The well thought out design with low side walls allows optimum cable connection. The components can be snapped out of the enclosure to facilitate cable-entry feeding. Notches in the mounting rails prevent the built-in components from being twisted out of place.
Check out HARDO brand control stations
HARDO explosion-proof control stations are an excellent alternative to well-known global manufacturers. They are certified for use in zones 1, 2, 21 and 22. We supply all control stations with accessories according to the investor’s requirements.
CEAG control stations can be combined according to customers‘ specifications. Quick fixing allows up to three CEAG built-in components, such as signal lamps, pushbuttons and switches, to be snapped on a rail in the enclosure. The enclosures consist of low-temperature impact-resistant thermoplastic which fulfils the requirements of EN 60079 and provides a high resistance to chemicals. The well thought out design with low side walls allows optimum cable connection. The components can be snapped out of the enclosure to facilitate cable-entry feeding. Notches in the mounting rails prevent the built-in components from being twisted out of place.
CEAG‘s optional mounting plates offer a time-saving fixing technique. Coupling pieces link enclosures to each other and prevent them from being twisted out of place. Alternatively, metal screws and flanges can be used for mounting – the metal flanges also enable external earthing.
The built-in components differ in size. The diverse enclosure types allow variable combinations of these components. Example diagrams of the enclosure types show the placement options for the built-in components with numbers or predefined positions.
Free mounting areas can be provided for retrofitting certified CEAG components. These are then factory sealed with blanking elements.
- Flat side walls
- Quick fixing for all built-in components
- High chemical resistance
- Different enclosures can be combined
Ex-control stations
- enclosures moulded plastic GHG 41 / 43
- enclosures GHG 413 / 414
- enclosures GHG 44
- enclosures GHG 443
- enclosures GHG 44. 33
Built-in components
- pushbutton
- key-operated pushbutton
- key-operated switch
- mushroom-head pushbutton
- mini-control switch
- potentiometer
- signal lamp
- measuring instrument AM 45/AM 72
- control switch Ex 23 and Ex 29
- terminals